Customization: | Available |
---|---|
Separator Type: | PP |
Negative Materials: | / |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type
|
Unit
|
Test Standard
|
Requirements
|
|||
Thickness
|
μm
|
GB/T 6672-2001
|
16±2
|
20±2
|
40±2
|
|
Surface Density
|
g/m2
|
GB/T 24218.1-2009
|
6~11
|
8~13
|
/
|
|
Porosity
|
%
|
GB/T 24218.1-2009
|
35~45
|
37~47
|
40-50
|
|
Gurley
|
S/100mL
|
GB/T 458-2008
|
190~390
|
250~450
|
500-800
|
|
Tensile Strength
|
MD
|
Mpa
|
GB/T 1040.3-2006
|
≥100
|
≥100
|
≤1.5
|
TD
|
≥25
|
≥25
|
≤1.0
|
|||
Shrinkage
|
MD
|
%
|
GB/T 12027-2004(90±2ºC, 1h)
|
≤1.5
|
≤1.5
|
≥100
|
TD
|
≤1.0
|
≤1.0
|
≤30
|
|||
Puncture Strength
|
N*
|
GB/T 10004-2008
|
≥2.2
|
≥2.8
|
≥5.0
|
Project
|
Unit
|
Measuring Instruments
|
Technical data
|
|
Material
|
/
|
DSC(Diamond N5360022)
|
PP
|
|
Porosity
|
%
|
Analytical balance(FA2004N)
|
42±3
|
|
Thickness
|
um
|
Mahr Thickness tester(C1216)
|
25±2
|
|
Width
|
mm
|
Straight steel ruler
|
Customized
|
|
Areal density
|
g/m2
|
Analytical balance(FA2004N)
|
13.2±1.0
|
|
Air Permeability
|
s/100ml
|
Analytical balance(FA2004N)
|
350±100
|
|
Puncture Strength
|
g
|
Puncture instrument (CMT6202)
|
≥400
|
|
Tensile Strength
|
MD
|
Kgf/cm2
|
Electronic tension machine (CMT8102)
|
≥1400
|
TD
|
≥130
|
|||
Thermal contraction (115ºC/16H)
|
MD
|
%
|
Drying oven(DHG-9023),
|
≤3.0
|
TD
|
Straight steel ruler
|
≤0.5
|