Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Machine describe
TOB-512-3LP is mainly composed of a communication interface and a battery detection cabinet. The battery testing cabinet is composed of battery clamp and a plate body to placing fixture, a constant current constant voltage source, a registration control circuit, a sampling circuit, a single chip microcomputer and a control panel.
2. Main feature
2.1 Each equipment can do constant current constant voltage charging and constant current discharge testing for 512 pcs of cell which is within the voltage range.
2.2 Constant current and constant voltage power supply, constant current to constant voltage switching without impact, especially suitable for lithium ion battery charging requirements.
2.3 This equipment adopts AVR single-chip computer as the control center, and cooperates with the peripheral sampling circuit, which can be controlled by the upper computer. When connected to the computer, the complete charge and discharge curve of all channels can be saved. Or it can be separated from the upper computer and operated by the control panel to complete constant current and constant voltage charging, constant current discharge test, etc.
2.4 Each battery has its own independent constant current and constant voltage source, and the self-forming loop does not affect each other.
2.5 A light-emitting diode is mounted on each of the battery fixtures as an operational status display, and when the discharge is completed, it can be used to indicate battery capacity sorting.
2.6 Real-time detection each battery voltage. When charging, first constant current charging, when the battery voltage reaches the set value, it will smoothly switch to constant voltage charging, and when the set time or current termination condition is satisfied, the charging ends. When constant current discharging, the battery voltage is lower than the set value, the discharge ends and the corresponding battery indicator lights up.
2.7 With power-down protection function, the original workflow can continue to run after the power back.
2.8 The upper computer can set 32 working step parameters and 256 cycles. Each upper computer can connect 1 to 15 sets of single-chip microcomputer system. (suggest below 10 sets)
2.9 Supporting software features
Model |
TOB-512-3LP |
Channel No. |
512 |
Workflow control method |
Whole equipment control |
Charging mode |
Constant voltage, constant current |
Charge cutoff condition |
Voltage, current, time, capacity |
Discharge mode |
Constant current |
Discharge cutoff condition |
Voltage, time, capacity |
Sampling inspection cycle |
≤10s |
Voltage measurement range |
0~5V, Resolution 1mV |
Battery voltage range |
Charge: 0~4.5V Discharge: 4.5~2.0V |
Constant voltage range |
3~4.5V |
Voltage accuracy |
± (0.05%RD+0.1%FS) |
Current range |
Charge: 0.015-3A Discharge: 0.015-3A, Resolution 1mA |
Current accuracy |
± (0.1%RD+0.1%FS) |
Time set range |
Any setting within 0~30000 minutes, the time unit is min |
Time accuracy |
≤±0.1% |
Clamp type |
Polymer clamp |
Clamp adjust range |
70mm |
Support battery type |
Pouch cell |
Working power |
Three-phase four-wire system, AC380V±5%, 50HZ, 14.5KW |
Communication method |
RS485, Baud rate 57600 |
Dimension |
L1440 × W500 × H1840mm |
Working environment |
0-40ºC |
Full load operating current |
Phase line up to 15A, zero line up to 3A |
Startup current |
Air switch closing moment about 60A |
Net weight |
About 350kg |
System main configuration requirements |
Minimum configuration of computer system: CPU above P4, memory above 2G, hard disk space above 200G, EGA/VGA color display, one CD-ROM, one mouse, MicrosoftTM Windows XP and above, one available RS232 serial communication port, Windows support Printer. The computer system is self-contained by the user, and the number of microcomputer systems is determined according to actual needs. |