Customization: | Available |
---|---|
After-sales Service: | 1year |
Warranty: | 1year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1 TOB-BTS-60V50A Battery test system is mainly used for Electric Car battery pack testing, it can test lithium battery pack voltage up to 60v with Max current 50A.
2 It can also test battery pack with protect board (PCB/PCM)
Project index | Parameter index | |
Input Power | AC 380V ±10% / 50Hz | |
Resolution | AD:15bit;DA:12bit | |
Input Resistance | ≥1MΩ | |
Input Power | 7848W | |
Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode | Independent Control | |
Voltage | Per Channel Voltage Range | Charge:300mV~60V;Discharge:2.5V~60V |
Discharge Min Voltage | 2.5V | |
Accuracy | ± 0.1% of FS | |
Stability | ± 0.1% of FS | |
Current | Per Channel Current Range | 250mA~50A |
Accuracy | ± 0.1% of FS) | |
Stability | ± 0.1% of FS | |
Power | Per Channel Output Power | 3000W |
Stability | ± 0.2% of FS | |
Time | Current Response Time | The Current rise Response Time is 20ms |
Step Time Range | 1s≤Single Step Time Range≤365*24 h, Time Form Support 00:00:00(h,min,s) |
|
Data Recording | Record Condition | Lower sampling time:100ms |
Lower sampling Voltage:150mV | ||
Lower sampling Current:5mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage Charge |
End Conditon | Voltage,Current,Relative Time,Capacity | |
Discharge | Discharge Mode | Constant Current Discharge |
End Condition | Current,Current,Relative Time,Capacity | |
Cycle | Loop Measure Range | 1~65535 times |
Per Loop Step No. | 254 | |
Nested Loop | Nested loop Function,Max Support 3 Layers | |
Protection | Software Protection | l Power-down Data Protection |
l Off-line Testing Function | ||
lSetting Protection Condition,Setting Parameter: Voltage Low limit,Voltage Upper limit,Current Low limit, Current Upper limit,Delay Time |
||
Hardware Protection | Addition Avoiding Reverseconnection Protection Model | |
Voltage and Current Testing Sample | 4-wire connecting | |
Noise | <80dB | |
Database | My SQL Databace | |
A Means of Communication of Upper Machine | TCP/IP Protocol | |
Data Output | EXCEL,TXT,Graph | |
Operation system | Offioce 2010 , Win 7 system | |
Communication Interface | Ethernet Port | |
Per Unit Main Channels No. | 1 | |
Dimensions | 18U,W*D*H:606*606*990(mm) |