| Customization: | Available |
|---|---|
| After-sales Service: | 1year |
| Warranty: | 1year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1 TOB-BTS-60V50A Battery test system is mainly used for Electric Car battery pack testing, it can test lithium battery pack voltage up to 60v with Max current 50A.
2 It can also test battery pack with protect board (PCB/PCM)
| Project index | Parameter index | |
| Input Power | AC 380V ±10% / 50Hz | |
| Resolution | AD:15bit;DA:12bit | |
| Input Resistance | ≥1MΩ | |
| Input Power | 7848W | |
| Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
| Channel Control Mode | Independent Control | |
| Voltage | Per Channel Voltage Range | Charge:300mV~60V;Discharge:2.5V~60V |
| Discharge Min Voltage | 2.5V | |
| Accuracy | ± 0.1% of FS | |
| Stability | ± 0.1% of FS | |
| Current | Per Channel Current Range | 250mA~50A |
| Accuracy | ± 0.1% of FS) | |
| Stability | ± 0.1% of FS | |
| Power | Per Channel Output Power | 3000W |
| Stability | ± 0.2% of FS | |
| Time | Current Response Time | The Current rise Response Time is 20ms |
| Step Time Range | 1s≤Single Step Time Range≤365*24 h, Time Form Support 00:00:00(h,min,s) |
|
| Data Recording | Record Condition | Lower sampling time:100ms |
| Lower sampling Voltage:150mV | ||
| Lower sampling Current:5mA | ||
| Record Frequency | 10Hz | |
| Charge | Charge Mode | Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage Charge |
| End Conditon | Voltage,Current,Relative Time,Capacity | |
| Discharge | Discharge Mode | Constant Current Discharge |
| End Condition | Current,Current,Relative Time,Capacity | |
| Cycle | Loop Measure Range | 1~65535 times |
| Per Loop Step No. | 254 | |
| Nested Loop | Nested loop Function,Max Support 3 Layers | |
| Protection | Software Protection | l Power-down Data Protection |
| l Off-line Testing Function | ||
| lSetting Protection Condition,Setting Parameter: Voltage Low limit,Voltage Upper limit,Current Low limit, Current Upper limit,Delay Time |
||
| Hardware Protection | Addition Avoiding Reverseconnection Protection Model | |
| Voltage and Current Testing Sample | 4-wire connecting | |
| Noise | <80dB | |
| Database | My SQL Databace | |
| A Means of Communication of Upper Machine | TCP/IP Protocol | |
| Data Output | EXCEL,TXT,Graph | |
| Operation system | Offioce 2010 , Win 7 system | |
| Communication Interface | Ethernet Port | |
| Per Unit Main Channels No. | 1 | |
| Dimensions | 18U,W*D*H:606*606*990(mm) | |