Customization: | Available |
---|---|
Warranty: | 1 Year |
Type: | Finished Batteries Tester |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ET44 Series | Measuring frequency up to 100 KHZ |
Test level 10 ~ 2000 mv | |
ET45 Series | Measuring frequency up to 100 kHz, Continuous adjustable frequency of 1Hz step by step |
Test level 10 ~ 2000 mv, 1 Hz continuous adjustable | |
Common | Support dc resistance (DCR), electrolytic capacitor measurement |
The internal bias voltage output 0 mv ~ 1500 mv | |
3.5 inch TFT display, five shows | |
Communications: USB Device, RS232 , Handle, | |
Data record function (maximum, minimum, average) | |
Support SCPI communication protocol | |
Provide the system Settings, can according to need to configure the Chinese or English, buzzer, screen brightness, etc. | |
Basic measurement accuracy of 0.1% | |
Manual and automatic range | |
With open circuit and short circuit calibration function | |
Comparator separation (5), alarm function |
Model | ET4401 | ET4402 | ET4410 | ET4501 | ET4502 | ET4510 | |||
Testing frequency | 10Points(100,120, 200,400, 800,1K,2K,4K, 8K,10K) |
12Points(100,120, 200,400,800,1K, 2K,4K,8K, 10K,15K,20K) |
16 Points(100,120,200, 400,800,1K,2K, 4K,8K,10K, 15K,20K,40K, 50K,80K,100K) |
10Hz ~ 10kHz continuously adjustable, 1Hz step |
10Hz ~ 20kHz continuously adjustable, 1Hz step |
10Hz ~ 100kHz continuously adjustable, 1Hz step | |||
Display screen | 3.5" TFT LCD screen | ||||||||
Number of display digits | Principal parameter: 5 digit, Secondary parameter: 5 digit | ||||||||
Measured parameter: | Principal parameter: L/C/R/Z, Secondary parameter: X/D/Q/θ/ESR | ||||||||
Measurement range | L:0.001µH~9999H, C:0.001pF~99.999mF, R:0.0001Ω~99.99MΩ | ||||||||
Basic accuracy | 0.10% | ||||||||
Measuring display speed | 2 time/s (slow), 4 times/s (medium), 8 time/s (fast) | ||||||||
Internal bias | 0-1500mV adjustable, at a step of 1mV. | ||||||||
Testing level | Six fixed level(0.1V,0.3V,0.6V,1V,1.5V,2V) | 0.1V ~ 2V,continuously adjustable, 1mV step | |||||||
Signal source output impedance | 30Ω,100Ω | ||||||||
Calibration function | Open circuit calibration, short circuit calibration | ||||||||
Screening function | The limit range of screening can be set to -50%~+50%, and the fixed points are 1%, 5%, 10% and 20%. | ||||||||
Comparator | 5 groups sorting,3 groups of qualified setting, one group of unqualified setting, one group of auxiliary setting | ||||||||
Interfaces | standard: RS232, USB Device, Handler ; | ||||||||
Others | Support dc resistance (DCR), electrolytic capacitor measurement model,Adjustment of backlight brightness, Chinese and English are optional |