• Battery Tester 2 Channel Bipotentiostat for Lithium Battery
  • Battery Tester 2 Channel Bipotentiostat for Lithium Battery
  • Battery Tester 2 Channel Bipotentiostat for Lithium Battery
  • Battery Tester 2 Channel Bipotentiostat for Lithium Battery
  • Battery Tester 2 Channel Bipotentiostat for Lithium Battery
  • Battery Tester 2 Channel Bipotentiostat for Lithium Battery

Battery Tester 2 Channel Bipotentiostat for Lithium Battery

After-sales Service: 1 Year
Warranty: 1 Year
Type: Batteries Monomer Tester
Test Region: Potentiostat Galvanostat
Application: Lithium-ion Battery
Customized: Customized
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
TOB-CS-2350
Current Control Range
± 1A
Current Sensitivity
1PA
Compliance Voltage
±21V
Maximum Current Output
1A
Transport Package
Wooden Box
Trademark
TOB
Origin
China
Production Capacity
10000 Set/Month

Product Description

Battery Tester 2 Channel Bipotentiostat For Lithium Battery
Battery Tester 2 Channel Bipotentiostat for Lithium Battery

 

 

TOB-CS-2350 bipotentiostat is developed from single channelTOB-CS-350 potentiostat/galvanostat. There are two s ets of built-in potentiostat /galvanostat. The two channels can conduct same or different experiments ind ependently/simultaneously.

If the user only chooses to use the main channel, thenTOB-CS-2350 turns to be aTOB-CS-350. Apart from all functi ons thatTOB-CS-350 single-channel potentiostat has,TOB-CS-2350 can especially be used to do RRDE and HDT.

 

Applications

( 1) Electrosythesis, electrodeposition (electroplating), anodic oxidation, electrolysis

(2) Oxygen reduction reaction(ORR), oxygen evolution reaction (OER), Hydrogen evolution reaction(HE R), carbon dioxide reduction.

(3) Energy and materials (Li-ion battery, solar cell, fuel cell, supercapacitor), advanced function materials, and sensor.

(4) Corrosion behavior of metals, and anti-corrosion evaluation

(5) Fast evaluation of inhibitor, water quality stabilizer, coating, and cathodic protection efficiency.

 

Rotating ring-disk electrode(RRDE)

Oxidation/reduction reaction system: while measuring the polarization curve of disk electrode, keep the ri ng electrode at a fixed polarization potential, and thus detect the intermediates of reaction on the disk ele ctrode. It becomes the typical fluid dynamics method that detects reaction intermediates and studies elec trode reaction mechanism

 

Hydrogen diffusion test(HDT)

Two potentiostats are combined with Devnathan-Stachurski (dual cell). By measuring cathode hydrogen charging (the left cell) and anode oxidation current of hydrogen atoms (the right cell), it can further calcul ate the diffusion coefficient of hydrogen atoms in the metal and hydrogen flux.

 

 

Potential control range  Main Channel: ± 10V
Slave Channel: ± 10V
Current control range  ± 1A
Potential control accuracy  0. 1% ×full range±1mV
Current control accuracy  0. 1% ×full range
Potential resolution  10μV (>100Hz), 3 μV (<10Hz)
Current sensitivity 1pA
Rise time  < 1 μs (<10mA), < 10μs (<2A)
Reference electrode input impedance  1012Ω||20pF
Current range  2A~2nA, 10 ranges
Compliance voltage  ±21V
Maximum current output  1A
CV and LSV scan rate  0.001mV~ 10,000V/s
CA and CC pulse width  0.0001~65,000s
Current increment during scan  1mA@1A/ms
Potential increment during scan  0.076mV@ 1V/ms
SWV frequency 0.001~ 100 kHz
DPV and NPV pulse width  0.0001~ 1000s
AD data acquisition  16bit@1 MHz,20bit@1 kHz
DA Resolution  16bit, setup time:1 μs
Minimum potential increment in CV  0.075mV
IMP frequency  10μ Hz~ 1MHz
Low-pass filters Covering 8-decade
Potential and current range  Automatic
Electrochemical impedance Spectroscopy(EIS)
Signal generator
Frequency range  10μ Hz~ 1MHz
AC amplitude  0mV~2500mV
DC Bias -10V ~ +10V
Output impedance  50Ω
Waveform  sine wave, triangular wave and square wave
Wave distortion  < 1%
Scanning mode  Logarithmic/linear, increase/decrease
Maximum load capacitance  1nF ;Maximum load inductance:10μ H
Signal analyzer
Integral time  10ms or the longest time of a cycle
Maximum  106 cycles or 105s
Measurement delay  0~ 105s
DC offset compensation
Potential automatic compensation range  -10V ~ +10V
Current compensation range  - 1A~+ 1A
Bandwidth 8-decade frequency range, Automatic and manual setting
PC and O/S requirement
Communications Interface  isolated Universal Serial Bus (USB 2.0)
Operating System  Windows 2000/NT/XP/7/8/ 10

Battery Tester 2 Channel Bipotentiostat for Lithium Battery
Battery Tester 2 Channel Bipotentiostat for Lithium Battery
Battery Tester 2 Channel Bipotentiostat for Lithium BatteryBattery Tester 2 Channel Bipotentiostat for Lithium BatteryBattery Tester 2 Channel Bipotentiostat for Lithium Battery
Battery Tester 2 Channel Bipotentiostat for Lithium Battery
Battery Tester 2 Channel Bipotentiostat for Lithium BatteryBattery Tester 2 Channel Bipotentiostat for Lithium BatteryBattery Tester 2 Channel Bipotentiostat for Lithium BatteryBattery Tester 2 Channel Bipotentiostat for Lithium BatteryBattery Tester 2 Channel Bipotentiostat for Lithium Battery
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now