• 512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester
  • 512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester
  • 512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester
  • 512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester
  • 512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester

512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester

After-sales Service: 1year
Warranty: 1year
Type: Pouch Cell Battery Test
Test Region: Charge and Discharge
Application: Polymer Battery
Customized: Customized
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
TOB-512-2LP
Transport Package
Cartons
Trademark
TOB
Origin
China
Production Capacity
1000000/Month

Product Description

512 Channel Charge And Discharge Pouch Cell battery capacity tester
512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester

 

1. Each equipment can do constant current constant voltage charge and constant current discharge for 512 pcs of cell which is within the voltage range.

2. Constant current constant voltage power supply, constant current to constant voltage switching without impact, especially suitable for lithium ion battery charging requirements.

3. The device adopt AVR single-chip computer as the control center, and the peripheral sampling circuit is used. It can be controlled by the upper computer. When connected to the computer, the complete charge discharge curve of all channels can be saved, or it can be separated from the upper computer and operated by the control panel, the constant current and voltage charging, constant current discharge test, time sorting and other works can be completed.

4. Each battery has its own independent constant current and constant voltage source, and the self-forming loop does not affect each other.

5. A LED is installed on each battery clamp as an operational status display, and when the discharge is completed, it can be used to indicate battery capacity sorting.

6. Real-time detection each battery voltage. when charging, first constant current charging, when the battery voltage reaches the set value, it will smoothly transfer to constant voltage charging. when the set time or current termination condition is satisfied, the charging ends. When the constant current is discharged, when the battery voltage is lower than the set value, the discharge ends and the corresponding battery indicator lights up.

7. With power-down protection function, the original workflow can continue to run after the power back.

8. The upper computer can set 32 working step parameters and 256 cycles. Each upper computer can connect 1 to 15 sets of single-chip microcomputer system. (suggest below 10 sets)

9. Supporting software features

1)Use the graphical operation interface to display data such as voltage, current, time, and capacity of each battery, and display the corresponding working status and abnormal conditions in various colors.

2)Arbitrary segmented battery capacity indication (up to 100 segments)

3)The data points can be recorded according to the changing conditions of voltage, current and time to form a complete charging and discharging curve data, and the time interval of the curve data points is ≤10 seconds.

4)Battery sorting function under various conditions (capacity, time, open circuit voltage, discharge platform, etc.)

5)Automatic calculation of constant current charging ratio, capacity loss, discharge efficiency, average voltage, median voltage, etc.

6)Operator permission setting, hierarchical operation.

7)Can display charge and discharge curve, cycle diagram.

 

Model

TOB-512-2LP

Channel No.

512

Workflow control method

Whole Cabin control

Charging mode

Constant voltage, constant current

Charge cutoff condition

Voltage, current, time, capacity

Discharge mode

Constant current

Discharge cutoff condition

Voltage, time, capacity

Sampling inspection cycle

≤10s

Voltage measurement range

0~5V, Resolution 1mV

Battery voltage range

Charge: 0~4.5V  Discharge: 4.5~2.5V

Constant voltage range

3~4.5V

Voltage accuracy

±(0.05%RD+0.1%FS)

Current range

Charge: 0.01-2A, Discharge :0.01-2A, Resolution:1mA

Current accuracy

±(0.1%RD+0.1%FS)

Time Set Range

Any setting within 0~30000 minutes, the time unit is min

Time accuracy

≤±0.1%

Clamp type

Four-wire method fixture

Clamp adjust range

70mm

Support battery type

Pouch cell

Voltage source

3 phase 4 wire, AC380V±5%, 50HZ, Power consumption 9.5KW

Communication method

RS485, Baud rate 57600

Machine size

L1440 x W500 x H1840mm

Working environment

Temperature: 0-40ºC, related temperature≤85%

Full load operating current

Phase line up to 15A, zero line up to 3A

Device startup current

Air switch closing moment about 60A

N.W

About 300kg

System main

configuration requirements

Minimum configuration of computer system: CPU above P4, memory above 2G, hard disk space above 200G, EGA/VGA color display, one CD-ROM, one mouse, MicrosoftTM Windows XP and above, one available RS232 serial communication port, Windows support Printer. The computer system is self-contained by the user, and the number of microcomputer systems is determined according to actual needs.

512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester
512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester512 Channel Charge and Discharge Pouch Cell Battery Capacity Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now