Customization: | Available |
---|---|
After-sales Service: | 1year |
Warranty: | 1year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Product name and model |
Battery constant temperature test system(TOB-SP250) |
2. Sample limit | This test equipment prohibits: 1,Test or storage of corrosive material samples 3,Test or storage of strong electromagnetic emission source samples 4,Testing or storage of radioactive material samples 5,Test or storage of samples of highly toxic substances 6,Explosive and volatile samples may be generated during testing or storage |
3. Volume, size and weight | |
a) Nominal volume | 162 L |
b) Inner box size | Width 460mm ×Depth 400mm ×Height 880mm |
c) Dimensions | Width 570mm × Depth 570mm ×Height 1530mm |
d) Weight | 90KG |
e) Power supply | 220V 2KW |
4. Performance | |
a) Test environment | The ambient temperature is+5~+40ºC,Relative humidity≤85%,Without sample in the test box |
b) Testing method |
GB/T 5170.2-2008 Temperature test equipment GB/T 5170.5-2008 Damp heat test equipment |
c) Temperature range | 0ºC~+60ºC |
d) Temperature fluctuation | ≤0.5ºC(Note: If expressed according to GB/T5170.2-1996, the fluctuation is ≤±0.25ºC) |
e) Temperature deviation | ±1ºC |
f) Temperature uniformity | Less than or equal to ±1ºC |
g) Heating time | 3ºC/min(Average heating rate) |
h) Cooling time | 0.5ºC/min(Average cooling rate) |
i) Meet the test method |
GB/T2423.1-2008(IEC60068-2-1:2007)Low temperature test method Ab GB/T2423.2-2008(IEC60068-2-2:2007) High temperature test method Bb GJB150.4-1986 Low temperature test GJB150.3-1986 High temperature test GB/T2423.3-2006(IEC60068-2-78:2007)damp heat test steady state Cab GB/T2423.4-2008(IEC60068-2-30:2005)Alternate humidity and temperature Db GJB150.9-1986 Damp heat test (The load per cubic meter is not more than 35kg/m3 of the heat capacity of the steel, and there is no active humidity and heat load during the damp heat test) |
5. Structure | |
a)Insulation enclosure structure |
|
b)Air conditioning channel |
|
c)Standard configuration of test chamber |
3.Equipent interior lighting (high efficiency and long life energy-saving lamp)
(The cumulative total load of samples in the box does not exceed: 80kg) |
d)Door | Single hinged door (right hinge when facing the cabinet), equipped with observation window and lighting lamp |
e)Control panel | Controller display, power switch and status indicator |
f)Machinery room | Refrigeration unit, drain hole Condensing fan, condenser air inlet |
g)Power distribution control cabinet | Integrated circuit board, air switch, button switch |
h)Heater |
|
i)Power cord hole and drain hole | Located on the back of the box |
Refrigerating system | |
Working method A | Adopt one-level compression |
Refrigeration Compressors | Fully enclosed low noise rotor compressor |
Evaporator | Finned tube heat exchanger (also used as a dehumidifier) |
Condenser | Air-cooled: finned tube heat exchanger. |
Throttling device | Expansion valve + capillary |
Plate heat exchanger | Stainless steel brazed plate heat exchanger |
a) Refrigerator control method |
|
b) Refrigerant | R134a (the ozone depletion index is all 0, R23 is adopted by the cascade principle system) |
6. Electrical control system | 9-pic |
a) Controller model | Shanghai 9- Pic Controller |
Monitor | JTSH200:5 inch, |
Operation mode | Program method, fixed value method |
Setting method | JTSH200 Chinese menu (freely selectable), key-screen input |
Program capacity |
JTSH200
|