Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1 TOB-CT4008-5V6A-S1 Battery tester equipment is an eight-channel battery analyzer to analyze polymer battery and cylindrical batteries from 0.5mA to 6A, up to 5V.
2 This battery test system provides most applications in battery testing fields such as electrode materials research, battery performance test, small-scale battery formation, capability grading, battery pack testing and etc.
3 TOB-CT-4000 Testing system has more quick sampling speed, attached with DC Resistance testing function. It also add with Channel parallel function which can enlarge the current up to twice of the normal range.
4 If you use this tester to test Super capacitor, please choose the model TOB-CT-4008-S1-F, with the min discharge voltage up to 0 V, Suitable for super capacitor, NI-MH battery, Nickel-chromium battery and all kind of rechargeable battery testing.
Model |
TOB-CT-4008-5V6A-S1 |
|
Input Power |
AC 220V ±10% / 50Hz |
|
resolution |
AD: 16bit DA: 16bit |
|
Input Resistance |
≥1MΩ |
|
Input Power |
425W |
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Constant voltage range |
25mV~5V |
Discharge Min Voltage |
The end of clamps can discharge to 1V, and the wire length of 2m can discharge to 1.5V |
|
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
|
Current |
Per Channel Current Range |
Range 1: 0.5mA-0.1A Range 2: 0.1A-3A Range3: 3A-6A |
Accuracy |
± 0.05% of FS |
|
Constant voltage cutoff current |
Range 1: 0.2mA Range 2: 6mA Range 3: 12mA |
|
Stability |
± 0.05% of FS |
|
Power |
Per Channel Output Power |
30W |
Stability |
± 0.1% of FS |
|
Time |
Current Response Time (10%FS~90%FS) |
<1ms |
Step Time Range |
≤(365*24 )hour/step Time Form Support 00 : 00 : 00 : 00 (h min s ms) |
|
Data Recording |
Record Condition |
Minimum Time Interval: 100ms |
Minimum Voltage Interval: 10mV |
||
Minimum Current Interval Range 1: 0.2mA Range 2: 6mA Range 3: 12mA |
||
Record Frequency |
10Hz |
|
Charge |
Charge Mode |
Constant Current Charge, Constant Voltage Charge, Constant Current and Constant Voltage Charge, CPC |
End Condition |
Voltage, Current, Relative Time, Capacity, -ΔV |
|
Discharge |
Discharge Mode |
CCD, CVD, CPD, CRD, Constant Current and Constant Voltage Discharge |
End Condition |
Voltage, Current, Relative Time, Capacity |
|
Pulse |
charge |
CCC, CPC |
Discharge |
CCD, CPD |
|
Min Pulse Width |
500ms |
|
Pulse Number |
A single pulse step supports 32 different pulses |
|
Automated Switch |
Automated swith from charge to discharge for each pulse |
|
End Condition |
Voltage, Test Time |
|
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function, Max Support 3 Layers |
|
Protection |
Software Protection |
Power-down Data Protection |
Off-line Testing Function |
||
Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time |
||
Hardware Protection |
Additional Anti-reverse Protection Model |
|
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
<55dB |
|
Database |
MySQL Database |
|
A Means of Communication of Upper Machine |
TCP/IP Protocol |
|
Data Output |
EXCEL, TXT |
|
Communication Interface |
Ethernet Port |
|
Per Unit Main Channels No. |
8 |
|
Dimensions (L*W*H mm) |
3U, 483*404*130 |