Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
GSM Pulse, Cyclic Voltammetry, Rate, Statistic capacity, Cycle life, constant current, constant power, constant resistance, constant voltage,voltage Scan (cyclic Voltammetry),Waveform import, Arithmetic Functions,1Khz AC impedance, BTS Series, Channel No., Rack Color, Measuring Range, Net With Reverse-connecting Protection.
The New 9 series battery tester has more bigger testing speed and more higher accuracy.
Technical Specifications
Project index |
Parameter index |
||
AC Input Power |
220/110V±10%/50Hz/60Hz |
||
Resolution |
AD:16bit;DA:16bit |
||
Impedance Input |
≥500MΩ |
||
Input Power |
250W |
||
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
||
Channel Control Mode |
Independent Control |
||
Voltage |
Per Channel Voltage Range |
0.7V~5V |
|
Lowest discharge voltage |
0.7V |
||
Accuracy |
± 0.02% of FS |
||
Stability |
±0.005% of FS |
||
Current |
Multi Range |
Rang1: 0.1uA---150uA ± 30nA |
|
Rang2: 150uA---5mA ± 1uA |
|||
Rang3: 5mA---150mA ± 30uA |
|||
Rang4: 150mA---5A ± 1mA |
|||
Accuracy |
± 0.02% of FS |
||
Stability |
±0.005% of FS |
||
Power |
Per Channel Max. Output Power |
25W |
|
Stability |
± 0.01% of FS |
||
Time |
Current Rise Time |
The Current gets to (10%-90%) Hardware Rise Time is 100μs |
|
Step Time Range |
Single Step Time Rang>=10ms |
||
Data Recording |
Record Condition |
Lower sampling time: >=1ms |
|
Lower sampling Voltage:>= 1mV |
|||
Lower sampling Current: :>= 100nA |
|||
Record Frequency |
1000Hz |
||
Charge |
Charge Mode |
Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage Charge,Constant Power Charge |
|
End Conditon |
Voltage,Current,Relative Time,Capacity |
||
Discharge |
Discharge Mode |
Constant Current Discharge,Constant power Discharge, Constant resistance discharge, |
|
End Condition |
Current,Voltage,Relative Time,Capacity, |
||
Pulse Model |
Charge |
Constant Current Model;Constant Power Model |
|
Discharge |
Constant Current Model;Constant Power Model |
||
Min Pulse Width |
400μs |
||
Pulse Number |
Single Pulse Step Support 16 different Pulse |
||
Charge r To Discharge |
One Pulse Step Can Support Continuous Charge And Discharge Change |
||
End Condition |
Voltage,Relative Time, |
||
DCR Testing |
Support Custom Access Point And Count The DCR |
||
Cycle |
Loop Measure Range |
1~65535 times |
|
Max Steps Per Loop |
254 |
||
Nested Loop |
Nested loop Function,Max Support 3 Layers |
||
Protective Function |
Software Protection |
Power-down Data Protection |
|
• Off-line Testing Function |
|||
Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time |
|||
Hardware Protection |
Additional Anti-reverse Protection Model |
||
Voltage and Current Testing Sample |
4-wire connecting |
||
Noise Density |
<85dB |
||
Data Management |
MYSQL |
||
Communication Means |
TCP/IP Protocol |
||
Data Output |
EXCEL,TXT |
||
Communication Interface |
Ethernet Port |
||
No. Of Channels Per Unit |
4 |
Equipment Working Environment
Project index |
Parameter index |
Working Temperature |
0ºC- 40ºC |
Storage Temperature |
-10ºC- 50ºC |
Working Humidity |
≤70%RH |
Storage Humidity |
≤80%RH |