A Technical Specifications
Model | TOB-BTS-60V300A | |
Input Power | AC 220V ±10% / 50Hz | |
resolution | AD:16bit;DA:16bit | |
Input Resistance | ≥100KΩ | |
Input Power | 80000W | |
Voltage | Constant Voltage Range Control | 0.3V~60V |
Min discharge Voltage | 0V | |
Accuracy | ± 0.05% of FS | |
Stability | ± 0.05% of FS | |
Current | Per Channel output Range | 1.5A~300A |
Constant voltage Cutoff Current | 0.6A | |
Accuracy | ± 0.05% of FS | |
Stability | ± 0.05% of FS | |
Power | Single Channel Output Power | 18000W |
Stability | ± 0.1% of FS | |
Time | Current Response Time | Maximum current rise time 20ms (10% to 90% or 90% to 10%) |
Step Time Range | ≤(365*24 )hour/step; Time format supports 00: 00: 00.000 (h, min, s, ms) | |
Data Recording | Record Condition | Minimum Time Interval: 0.1s |
Minimum Voltage Interval: 120mV | ||
Minimum Current Interval : 600mA | ||
Record Frequency | 10Hz | |
Charge | Charge Mode | Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage Charge,CPC |
End Condition | Voltage,Current,Relative Time,Capacity | |
Discharge | Discharge Mode | CCD,CPD,CRD,CCVD,CVD |
End Condition | Voltage,Current,Relative Time,Capacity | |
Energy-saving efficiency | >65% (compared with conventional equipment) | |
Cycle | Loop Measure Range | 1~65535 times |
Max Steps Per Loop | 254 | |
Nested Loop | Nested loop Function,Max Support 3 Layers | |
Protection | Power-down Data Protection | |
Off-line Testing Function | ||
Setting Protection Condition, Setting Parameter: Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Low Capacity limit,Upper Capacity limit,Delay Time | ||
Additional Anti-reverse Protection Model | ||
IP protection level | Protection grade IP20 | |
Channel Features | Constant Current Source and Constant Voltage Source Adopt Double Closed-loop Structure |
|
Channel Control Mode | Independent Control | |
Voltage and Current Testing Sample | 4-wire connecting | |
Noise | <85dB | |
Database | MySQL Database | |
A Means of Communication of Upper Machine | TCP/IP Protocol | |
Data Output | EXCEL,TXT | |
Communication Interface | Ethernet Port | |
Server disk configuration | 500G | |
Server operating system | Windows 7 | |
Number of channels | 4 |
Project index | Parameter index |
Working Temperature | 0ºC~40ºC |
Storage Temperature | -10ºC~50ºC |
Working Humidity | ≤70% RH |
Storage Humidity | ≤80% RH |
Auxiliary channel (optional) | Type | Temperature, voltage |
Temperature range | -25ºC-110ºC | |
Accuracy | ±1ºC | |
Resolution | 0.1ºC | |
Voltage range | 0V~5V | |
Voltage accuracy | ± 1% of FS | |
Number of temperature auxiliary channels per channel (optional) | Can be filled in as needed (up to 248 temperature auxiliary channels can be used) | |
The number of auxiliary channels with voltage per channel (optional) | Can be filled in as needed (up to 248 voltage auxiliary channels can be used) | |
Auxiliary channel protection conditions | The auxiliary channel protection conditions can be set, and the parameters that can be set include: upper temperature limit, lower temperature limit, upper voltage limit, lower voltage limit, and single battery voltage difference | |
Remarks: Not compatible with the test of battery with protection board with soft-start function |